ACE HARDWARE CORP/PAINT DIV -- 186A128, 7-STAR ACE TONE LATEX SEMI-GLOSS C -- 8010-00N028829
=====================  Product Identification  =====================

Product ID:186A128, 7-STAR ACE TONE LATEX SEMI-GLOSS C
MSDS Date:10/01/1986
FSC:8010
NIIN:00N028829
=== Responsible Party ===
Company Name:ACE HARDWARE CORP/PAINT DIV
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Info Phone Num:312-720-0600
Emergency Phone Num:312-720-0600
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:ETHYLENE GLYCOL. VP: 0.1.
CAS:107-21-1
RTECS #:KW2975000
Fraction by Wt: 2%
OSHA PEL:50 PPM, C
ACGIH TLV:50 PPM, VAPOR, C
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:1-PROPANOL, 2-AMINO-2-METHYL-;
    (2-AMINO-2-METHYL-1-PROPANOL). VP: 0.8.
CAS:124-68-5
RTECS #:UA5950000
Fraction by Wt: <0.5%
OSHA PEL:20 PPM (MFR)
ACGIH TLV:10 PPM (MFR)

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IN A CONFINED AREA VAPORS IN
    HIGH CONCENTRATION ARE ANESTHETIC. IRRITANT TO SKIN AND UPPER
    RESPIRATORY SYSTEM. OVEREXPOSURE MAY RESULT IN LIGHTHEADEDNESS AND
    STAGGERING GAIT.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:CHRONIC PROBLEMS WITH RESPIRATORY
    SYSTEM MAY BE AGGRAVATED BY EXPOSURE TO VAPORS.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE FROM EXPOSURE, RESTORE BREATHING. KEEP WARM AND
    QUIET. SKIN: WASH AFFECTED AREAS THOROUGHLY WITH SOAP AND WATER.
    REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE RE-USE. EYES: FLUSH
    WITH  WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION. INGEST:
    CALL MD IMMEDIATELY .

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:199F,93C
Extinguishing Media:ALCOHOL FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    . WATER SPRAY MAY NOT BE EFTIVE. WATER MAY BE USED TO COOL CLSD
    CNTNRS TO PVNT PRESS BUILD-UP (SUPP DATA)
Unusual Fire/Explosion Hazard:EXTREME HEAT MAY CAUSE CLOSED CONTAINERS
    TO BURST.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINER CLOSED WHEN NOT IN USE.
    TRANSFER ONLY TO APPROVED CONTAINERS WITH COMPLETE AND APPROPRIATE
    LABELING. DOL STORGE CATEGORY - 3B.
Other Precautions:DO NOT TAKE INTERNALLY. KEEP OUT OF REACH OF
    CHILDREN. USE ONLY WITH ADEQUATE VENTILATION. AVOID BREATHING VAPOR
    AND SPRAY MIST. AVOID CONTACT WITH SKIN AND EYES.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERSONAL EXPOSURE CANNOT BE CONTROLLED BELOW
    APPLICABLE LIMITS BY VENTILATION, WEAR RESPIRATORY DEVICE APPROVED
    BY NIOSH/MSHA.
Ventilation:LOCAL EXHAUST PREFERABLE, GENERAL EXHAUST ACCEPTABLE BELOW
    TLV. REFER TO OSHA STDS. 1910.94, 1910.107, 1910.108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC:AND POSSIBLE AUTO IGNITION OR EXPLOSION WHEN EXPOSED TO
    EXTREME HEAT.

==================  Physical/Chemical Properties  ==================

HCC:V4
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Spec Gravity:1.22 
pH:8.5-9
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:66.52

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:EXTREME HEAT AND OPEN FLAME.
Hazardous Decomposition Products:BY FIRE: CO AND CO2.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
    INCINERATE CLOSED CONTAINERS. DISPOSE OF I/A/W FEDERAL, STATE AND
    LOCAL REGULATIONS REGARDING POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.