PHILLIPS PETROLEUM CO -- GASOLINE (ALL GRADES) PREMIUM UNLEADED, 130 -- 9140-00N040059
=====================  Product Identification  =====================

Product ID:GASOLINE (ALL GRADES) PREMIUM UNLEADED, 130
MSDS Date:03/31/1990
FSC:9140
NIIN:00N040059
=== Responsible Party ===
Company Name:PHILLIPS PETROLEUM CO
Address:12 D2 PHILLIPS BLDG
City:BARTLESVILLE
State:OK
ZIP:74004
Country:US
Info Phone Num:918-661-8327; 918-661-5952
Emergency Phone Num:918-661-3865; 918-661-8118
CAGE:46916
=== Contractor Identification ===
Company Name:PHILLIPS PETROLEUM CO
Address:613 ADAMS
Box:City:BARTLESVILLE
State:OK
ZIP:74004
Country:US
Phone:800-234-6603
CAGE:46935
Company Name:PHILLIPS PETROLEUM COMPANY
CAGE:46916

=============  Composition/Information on Ingredients  =============

Ingred Name:ING 12:BENZENE HAS PRDCD FETAL DEATH IN LAB ANIMALS &
    CAUSED CHROMOSOME CHANGES IN HUMANS & MUTATION CHANGES IN (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13:CELLS OF OTHER ORGANISMS. HLTH EFTS ATTRIBUTABLE TO
    BENZENE ARE NOT KNOWN TO OCCUR IN HUMANS EXPOSED TO (ING 15)
RTECS #:9999999ZZ

Ingred Name:ING 14:GAS.NOTE:TOLUENE(108-88-3)& LEAD CMPD IS ON NAVY
    LIST OF OCCUP CHEM REPRO HAZS. CONSULT WITH APPROP HLTH(ING 1)
RTECS #:9999999ZZ

Ingred Name:ING 15:PROFS CONCERNING LATEST HAZ LIST INFO & SAFE HNDLG &
    EXPOS RECS .
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:TRANSFER TO DISPOSAL DRUMS USING NON-SPARKING
    EQUIPMENT.
RTECS #:9999999ZZ

Ingred Name:OTHER PREC:CONTAM EQUIP: CONT IMMED SUPERVISOR FOR SPECIFIC
    INSTRUCTIONS BEFORE WORK IS INITIATED. WEAR PROT (ING 19)
RTECS #:9999999ZZ

Ingred Name:ING 18:EQUIP &/OR GARMENTS DESCRIBED IN PERSONAL PROT INFO
    IF EXPOS CNDTNS WARRANT. NOTE: PERSONAL PROT INFO IS (ING 20)
RTECS #:9999999ZZ

Ingred Name:ING 19:BASED UPON GEN INFO AS TO NORMAL USES & CNDTNS.
    WHERE SPECIAL/UNUSUAL USES/CNDTNS EXIST, IT IS SUGGESTED (ING 21)
RTECS #:9999999ZZ

Ingred Name:ING 20:THAT EXPERT ASSISTANCE OF INDUS HYGIENIST/OTHER
    QUALIFIED PROF BE SOUGHT.
RTECS #:9999999ZZ

Ingred Name:GASOLINE (INCLUDING INGREDIENTS 2 - 9)
CAS:8006-61-9
RTECS #:LX3300000
Fraction by Wt: 100%
OSHA PEL:300 PPM;500 PPM STEL
ACGIH TLV:300 PPM;500 PPM STEL

Ingred Name:BENZENE  (SARA III)
CAS:71-43-2
RTECS #:CY1400000
Fraction by Wt: <5%
OSHA PEL:1 PPM;5 PPM STEL
ACGIH TLV:10 PPM
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:TOLUENE  (SARA III)
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: <10%
OSHA PEL:200 PPM/150 STEL
ACGIH TLV:50 PPM; 9293
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:BENZENE, ETHYL-; (ETHYL BENZENE)  (SARA III)
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: <2%
OSHA PEL:100 PPM;125 PPM STEL
ACGIH TLV:100 PPM;125 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:P-XYLENE  (SARA III)
CAS:106-42-3
RTECS #:ZE2625000
Fraction by Wt: <3%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:M-XYLENE  (SARA III)
CAS:108-38-3
RTECS #:ZE2275000
Fraction by Wt: <6%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:O-XYLENE  (SARA III)
CAS:95-47-6
RTECS #:ZE2450000
Fraction by Wt: <3%
OSHA PEL:100 PPM;150 PPM STEL
ACGIH TLV:100 PPM;150 PPM STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ETHER, TERT-BUTYL METHYL; (METHYL TERT-BUTYL ETHER)  (SARA
    III)
CAS:1634-04-4
RTECS #:KN5250000
Fraction by Wt: <15%
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:BENZENE, 1,2,4-TRIMETHYL-; (1,2,4-TRIMETHYLBENZENE)  (SARA
    III)
CAS:95-63-6
RTECS #:DC3325000
Fraction by Wt: <3%
OSHA PEL:25 PPM
ACGIH TLV:25 PPM

Ingred Name:PLUMBANE, TETRAETHYL; (TETRAETHYL LEAD)  (SARA III)
CAS:78-00-2
RTECS #:TP4550000
Fraction by Wt: <0.25%
OSHA PEL:0.075 MG/M3, S
ACGIH TLV:0.1 MG/M3, S
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:EFTS OF OVEREXP:NERVES, KIDNEYS & REPRO SYS. BENZENE MAY
    PRDCE BLOOD CHANGES WHICH INCL REDUCED PLATELETS, (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11:REDUCED RED BLOOD CELLS, REDUCED WHITE BLOOD CELLS,
    APLASTIC ANEMIA & ACUTE NONLYMPHOCYTIC LEUKEMIA. (ING 13)
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:ACUTE:EYE/SKIN:MAY CAUSE SLIGHT IRRIT.
    INHAL:MAY CAUSE HDCH, NAUS, WEAK, SEDATION & UNCON. INGEST:MAY
    CAUSE IRRIT TO INTESTINES. MAY BE ASPIR INTO LUNGS IF SWALLOWED,
    WHICH MAY RSLT IN PULM EDEMA & CH EM PNEUM. CHRONIC:UNLEADED GAS
    HAS PRDCD CANCER IN LAB ANIMALS. NO COMPARABLE HLTH HAZ FOR CANCER
    IS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:BENZENE:KNOWN CARCIN(NTP)5'TH ANN RPT ON
    CARCIN:GRP 1(IARC)MONO.VOL SUP 7,P.120,'87;OSHA REGULTD
    CARCIN,2ACFR,1910.1028.
Effects of Overexposure:HLTH HAZ:KNOWN TO OCCUR IN HUMANS. UNLEADED GAS
    HAS PRDCD KIDNEY DMG IN MALE RATS ONLY. NO COMPARABLE HLTH HAZ FOR
    KIDNEY DISEASE IS KNOWN TO OCCUR IN HUMANS. GAS CNTNG LEAD
    ANTI-KNOCK CMPDS SHLD BE H NDLD IN SUCH A WAY TO MIN CONT W/BODY.
    LEAD CAN ACCUM IN BODY W/OVEREXP & CAUSE ILLNESS DUE TO EFTS ON
    BLOOD, (ING 11)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:EYE:FLUSH W/RUNNING WATER FOR AT LST 15 MINS. IF IRRIT
    DEVELOPS, SEEK MED ATTN. SKIN:WASH W/SOAP & WATER. IF IRRIT
    DEVELOPS, SEEK MED ATTN. INHAL:REMOVE FROM EXPOS. IF BRTHG CEASES,
    ADMIN ARTF RESP FO LLOWED BY OXYGEN. SEEK MED ATTN. INGEST:DO NOT
    INDUCE VOMIT. SEEK IMMED MED ASSISTANCE. NOTE TO MD:GASTRIC LAVAGE
    USING CUFFED ENDOTRACHEAL TUBE MAY BE PERFORMED AT YOUR DISCRETION.

=====================  Fire Fighting Measures  =====================

Flash Point:<-35F,<-37C
Lower Limits:1.5%
Upper Limits:7.6%
Extinguishing Media:DRY CHEMICAL, FOAM OR CARBON DIOXIDE (CO*2).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    . EVACUATE AREA OF ALL UNNEC PERS. SHUT OFF SOURCE, IF POSS. WATER
    FOG/SPRAY MAY BE USED TO COOL (SUPDAT)
Unusual Fire/Explosion Hazard:CARBON OXIDES & VARIOUS HYDROCARBONS
    FORMED WHEN BURNED. GASOLINES CNTNG TETRAETHYL LEAD WILL FORM LEAD
    FUMES WHEN BURNING. HIGHLY FLAMM VAPS WHICH ARE (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:EVACUATE AREA OF ALL UNNEC PERS. WEAR PROT
    EQUIP &/OR GARMENTS DESCRIBED IN PERSONAL PROT INFO IF EXPOS CNDTNS
    WARRANT. SHUT OFF SOURCE, IF POSS & CONTAIN SPILL. PROT FROM IGNIT.
    KEEP OUT OF WATER SOU RCES & SEWERS. ABSORB IN DRY, INERT MATL.
    (ING 17)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:AVOID CONT W/EYES, SKIN/CLTHG. AVOID
    BRTHG VAPS. WEAR PROT EQUIP &/OR GARMENTS DESCRIBED IN PERSONAL
    PROT INFO IF EXPOS CNDTNS WARRANT.
Other Precautions:DO NOT SIPHON BY MOUTH. STORE IN COOL, WELL-VENTED
    AREA AWAY FROM IGNIT SOURCES. PROVIDE MEANS OF CONTROLLING LEAKS &
    SPILLS. BOND & GROUND DURING LIQ TRANSFER. KEEP CNTNRS CLSD. PROT
    CNTNRS FROM PHYS ICAL DMG. PROT REQD FOR WORK ON (ING 18)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:FOR CONCENTRATIONS EXCEEDING RECOMMENDED
    EXPOSURE LEVEL, USE NIOSH/MSHA APPROVED AIR PURIFYING RESPIRATOR.
    WHEN ENTRY INTO/EXIT FROM CONCENTRATIONS OF UNKNOWN EXPOSURE, USE
    NIOSH/MSHA APPROVED SCBA.
Ventilation:USE ADEQUATE VENTILATION TO CONTROL EXPOSURE BELOW
    RECOMMENDED LEVELS.
Protective Gloves:VITON, NITRILE/POLYVINYL ALCHOHOL (PVA).
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:FULL BODY LONG-SLEEVED GARMENTS.
Work Hygienic Practices:WASH THORO AFTER HANDLING. IMMED REMOVE ANY
    CONTAM CLOTHING. LAUNDER CONTAM CLOTHING BEFORE REUSE.
Supplemental Safety and Health
VP:350-800 @ 20C. FL PT METH:ESTIMATED. FIRE FIGHT PROC:EXPOSED CNTNRS
    & EQUIP. DO NOT SPRAY WATER DIRECTLY ON FIRE - PROD WILL FLOAT &
    COULD BE REIGNITED ON SURF OF WATER. EXPLO HAZ:HVR/AIR MAY ACCUM 
    IN LOW AREAS &/OR SPREAD ALONG GROUND AWAY FROM HNDLG SITE.
    FLASHBACK ALONG VAP TRAIL MAY OCCUR.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>80F,>27C
Vapor Pres:SUPP DATA
Vapor Density:3-4
Spec Gravity:0.8 (H*2O=1)
Evaporation Rate & Reference:>1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED-ORANGE LIQUID; PUNGENT ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXYGEN & STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products:CARBON OXIDES, LEAD FUMES (FOR GRADES
    CNTNG TETRAETHYL LEAD) & VARIOUS HYDROCARBONS WHEN BURNED.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INSURE CONFORMITY W/ALL APPLIC FED, STATE &
    LOCAL DISP REGS. INCIN/OTHERWISE MANAGE IN RCRA PERMITTED WASTE
    MANAGEMENT FACILITY. RCRA CLASS - UNADULTERATED PROD AS WASTE:D001,
    FOR ALL GASOLINES; D008,  FOR GAS CNTNG TETRAETHYL LEAD.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.