SPRAYON PRODUCTS -- JOHN DEERE AG YELLOW TRY 3 YELLOW, 55863W25 -- 8010-00N079088
=====================  Product Identification  =====================

Product ID:JOHN DEERE AG YELLOW TRY 3 YELLOW, 55863W25
MSDS Date:05/11/1993
FSC:8010
NIIN:00N079088
=== Responsible Party ===
Company Name:SPRAYON PRODUCTS
Address:26300 FARGO AVE
City:BEDFORD HEIGHTS
State:OH
ZIP:44146
Country:US
Info Phone Num:216-292-7400
Emergency Phone Num:216-292-7400
CAGE:09800
=== Contractor Identification ===
Company Name:SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
Address:26300 FARGO AVENUE
Box:City:BEDFORD HEIGHTS
State:OH
ZIP:44146
Country:US
Phone:216-292-7400 OR 216-595-8634
CAGE:09800

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE (PROPELLANT); VP: 760.00
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 10%
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT

Ingred Name:PROPANE, 2-METHYL-; (2-METHYLPROPANE (PROPELLANT)) VP:
    760.00
CAS:75-28-5
RTECS #:TZ4300000
Fraction by Wt: 15%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:LACOLENE; (LT. ALIPHATIC HYDROCARBON SOLVENT) VP: 53.00
CAS:64742-89-8
Fraction by Wt: 10%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS) VP:
    2.00
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 10%
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:TOLUENE (SARA 313) (CERCLA) VP: 22.00
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: 5%
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:XYLENE (SARA 313) (CERCLA) VP: 5.90
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: <5%
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/150STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:ACETONE (SARA 313) (CERCLA) VP: 180.00
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 20%
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313) (CERCLA)
    VP: 70.00
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 10%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:EFTS OF OVEREXP: FROM APPROP HEALTH PROFESSIONALS
    CONCERNING LATEST HAZARD LIST INFO & SAFE HNDLG & EXPOS INFO .
RTECS #:9999999ZZ

Ingred Name:OTHER PREC: EXTING ALL FLAMES, PILOT LIGHTS & HEATERS; TURN
    OFF STOVES, ELEC TOOLS & APPLIANCES, & ANY OTHER (ING 11)
RTECS #:9999999ZZ

Ingred Name:ING 10: SOURCES OF IGNIT. CONSULT NFPA CODE. USE APPRVD
    BONDING & GROUNDING PROC. CONTENTS UNDER PRESS. DO NOT (ING 12)
RTECS #:9999999ZZ

Ingred Name:ING 11: PUNCTURE, INCIN/EXPOSE TO TEMP >120F. HEAT FROM
    SUNLIGHT, RADIATORS, STOVES, HOT WATER, & OTHER HEAT (ING 13)
RTECS #:9999999ZZ

Ingred Name:ING 12: SOURCES COULD CAUSE CONTR TO BURST. DO NOT TAKE
    INTERNALLY. KEEP OUT OF REACH OF CHILDREN. INTENTIONAL (ING 14)
RTECS #:9999999ZZ

Ingred Name:ING 13: MISUSE BY DELIBERATELY CONCENTRATING AND INHALING
    THE CONTENTS CAN BE HARMFUL OR FATAL.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF EYES, SKIN & RESP SYS.
    MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
    POSS DEATH. SIGNS & SYMPS: HDCH, DIZZ, NAUS & LOSS OF COORD ARE
    INDICATIONS OF EXCESS EXPOS TO VA PS/SPRAY MISTS. REDNESS &
    ITCH/BURNING SENSATION MAY INDICATE EYE/EXCESS SKIN EXPOS. CHRONIC:
    METHYL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ETHYL KETONE MAY INCR NERV SYS EFTS
    OF OTHER SOLVS. PRLNG OVEREXP TO SOLV INGS MAY CAUSE ADVERSE EFTS
    TO LIVER, URINARY, BLOOD-FORMING, CARDIOVASCULAR & REPRO SYS. RPTS
    HAVE ASSOC RPTD & PRL NG OVEREXP TO SOLVS W/PERM BRAIN & NERVSYS
    DMG. TOLUENE APPEARS ON NAVY OCCUP CHEM REPRO HAZ LIST. SEEK
    CONSULT (ING 9)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:INHAL: REMOVE FROM EXPOSURE. RESTORE BREATHING. KEEP WARM &
    QUIET. SKIN: WASH AFFECTED AREA THOROUGHLY W/SOAP & WATER. REMOVE
    CONTAMINATED CLOTHING & LAUNDER BEFORE REUSE. EYES: FLUSH W/LARGE
    AMOUNTS  OF WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.
    INGEST: NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON. DO
    NOT INDUCE VOMITING. GIVE SEVERAL GLASSES OF WATER. SEEK MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:<0F,<-18C
Lower Limits:1.0%
Upper Limits:12.8%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED, FOG NOZZ ARE
    PREF. WATER MAY BE USED TO COOL CLSD (SUP DAT)
Unusual Fire/Explosion Hazard:ISOLATE FROM HEAT, ELEC EQUIP, SPKS &
    OPEN FLAME. CLSD CONTRS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT.
    APPLICATION TO HOT SURF REQUIRES SPECIAL PREC. (SUP DAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:THIS COATING MAY CONTAIN MATLS
    CLASSIFIED AS NUISANCE PARTICULATES WHICH MAY BE PRESENT AT HAZ
    LEVELS ONLY DURING SANDING/ABRADING OF DRIED FILM.
Other Precautions:USE ONLY W/ADEQ VENT. AVOID BRTHG VAP & SPRAY MIST.
    AVOID CONT W/SKIN & EYES. KEEP AWAY FROM HEAT, SPKS & OPEN FLAME.
    VAPS WILL ACUUM READILY & MAY IGNITE EXPLO. DURING USE & UNTIL ALL
    VAPS ARE GONE:  KEEP AREA VENTD; DO NOT SMOKE; (ING 10)

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF PERS EXPOS CANNOT BE CONTROLLED BELOW APPLIC
    LIMS BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP APPRVD
    BY NIOSH. WHEN SANDING/ABRADING DRIED FILM, WEAR DUST/MIST RESP
    APPRVD BY NIOSH FOR D UST WHICH MAY BE GENERATED (SUP DAT)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS IS MAINTAINED
    BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS (SUP DAT)
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYEWASH AND DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
FIRE FIGHT PROC: CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO
    WHEN EXPOSED TO EXTREME HEAT. EXPLO HAZ: DURING EMER CNDTNS OVEREXP
    TO DECOMP PRODS MAY CAUSE A HLTH HAZ. SYMPS MAY NOT BE IMMED A
    PPARENT. OBTAIN MED ATTN. RESP PROT: FROM THIS PROD, UNDERLYING
    PAINT/ABRASIVE. VENT: 1910.94, 1910.107, 1910.108.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:0.71
Evaporation Rate & Reference:FASTER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER
Percent Volatiles by Volume:92

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
    MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
    RCRA 40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE
    APPLIC EPA HAZ WASTE NUMBERS. DO NOT INCIN. DEPRESSURIZE CONTR.
    DISP OF I/A/W FED,	STATE & LOC REGS REGARDING POLLUTION.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.