MANTEK -- PRO POWER, 0382 -- 7930-00N047255
=====================  Product Identification  =====================

Product ID:PRO POWER, 0382
MSDS Date:04/13/1993
FSC:7930
NIIN:00N047255
=== Responsible Party ===
Company Name:MANTEK
Box:152170
City:IRVING
State:TX
ZIP:75015
Country:US
Info Phone Num:214-438-4144 EXT. 013
Emergency Phone Num:214-438-4144 EXT. 013
CAGE:64796
=== Contractor Identification ===
Company Name:NCH CORP
Address:2727 CHEMSEARCH BLVD
Box:152170
City:IRVING
State:TX
ZIP:75015-2170
Country:US
Phone:972-438-0563
CAGE:20913
Company Name:NCH CORP  / MANTEK DIV
Address:1320 E NORTHGATE DRIVE
Box:152170
City:IRVING
State:TX
ZIP:75015-2170
Country:US
Phone:800-527-9919
CAGE:64796

=============  Composition/Information on Ingredients  =============

Ingred Name:WASTE DISP METH:AND FEDERAL REGULATIONS.
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:MINERAL SPIRITS; (ALIPHATIC PETROLEUM DISTILLATE).
    LD50:(ORAL,RAT) 28 GM/KG 2.
CAS:64742-47-8
OSHA PEL:300 PPM (MFR)
ACGIH TLV:300 PPM (MFR)

Ingred Name:CYCLOHEXENE, 1-METHYL-4-(1-METHYLETHENYL)-,(R)-;
    (D-LIMONENE). LD50:(ORAL,RAT)4400 MG/KG
CAS:5989-27-5
RTECS #:GW3600000
OSHA PEL:N/K 
ACGIH TLV:>50 PPM (MFR)

Ingred Name:SUPDAT:VAP LIMS IN WORKPLACE. LIMONENE HAS BEEN SHOWN TO BE
    A DERMAL SENSITIZER. IN ANIMAL STUDIES, (ING 4)
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ING 3:REPROD & TERATOGENIC EFTS HAVE BEEN SHOWN.
    IMPLICATIONS FOR HUMANS HAS NOT BEEN DETERMD ALTHOUGH TYPICAL (ING
    5)
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ING 4:USE OF PROD SHOULD NOT POSE ANY SUBSTANTIAL RISK.
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:FIRST AID PROC:GLASSES OF WATER. SEEK MED ATTN IMMED.
RTECS #:9999999ZZ
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MAY CAUSE IRRIT. SKIN:MAY
    CAUSE IRRIT & DERMAT. INHAL:HIGH CONC AT ELEVATED TEMPS ARE IRRIT
    TO RESPIR TRACT & MAY CAUSE HDCH, DIZZ, ANESTH, DROW. HIGH VAP CONC
    (GREATER THAN APPROX 700 PPM,  ATTAINABLE AT ELEVATED TEMPS WELL
    ABOVEAMBIENT) ARE IRRIT TO EYES & RESPIR TRACT, MAY CAUSE HDCHS
    (EFTS OF OVEREXPS)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:AND DIZZ, ARE ANESTH & MAY HAVE CNS
    EFTS. DIRECT CONT W/EYES WILL CAUSE IRRIT. RPTD/PRLNG SKIN CONT CAN
    CAUSE IRRIT. CHRONIC:PRLNGD/RPTD SKIN CONT TENDS TO REMOVE SKIN
    OILS POSSIBLY LEADING T O DERMAT. ING 1:LAB ANIMAL STUDIES
    HAVESHOWN THAT PRLNGD & RPTD BRTHG INHAL EXPO TO LIGHT HYDROCARBON
    VAPS IN (SUPDAT)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHAL:IF OVERCOME BY VAP, REMOVE FROM EXPOS & CALL MD IMMED.
    IF BRTHG IS IRREGULAR/HAS TOPPED, START RESUSCITATION, ADMIN OXYG,
    IF AVAIL. EYE:FLUSH WITH CLEAR WATER FOR AT LEAST 15 MINS OR UNTIL
    IRRIT  SUBSIDES. IF IRRIT PERSISTS, CALL MD. SKIN:REMOVE CONTAM
    CLTHG & WASH SKIN THORO W/SOAP & WATER. IF IRRIT OCCURS, APPLY A
    LANOLIN-RICH SKIN CREAM. INGEST:DO NOT INDUCE VOMIT. GIVE 3 TO 4
    (ING 6)

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:143F,62C
Lower Limits:0.7
Upper Limits:0.1
Extinguishing Media:CO*2, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:FUMES SMOKE, CARBON MONOXIDE, ALDEHYDES
    AND OTHER DECOMPOSITION PRODUCTS, IN THE CASE OF INCOMPLETE
    COMBUSTION.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SHUT OFF & ELIMINATE ALL IGNIT SOURCES. KEEP
    PEOPLE AWAY. RECOVER FREE PRODUCT. ADD SAND, EARTH OR OTHER
    SUITABLE ABSORBANT TO SPILL AREA. PLACE INTO LABELED DRUMS FOR
    PROPER DISPOSAL.
Neutralizing Agent:NONE.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CNTNRS CLOSED WHEN NOT IN USE. DO
    NOT HANDLE OR STORE NEAR HEAT, SPARKS, FLAMES, OR STRONG OXIDANTS.
Other Precautions:ADEQUATE VENTILATION IS REQUIRED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA APPROVED SUPPLIED-AIR RESPIRATOR IN
    CONFINED OR ENCLOSED SPACES, IF NEEDED. NORMALLY NOT NEEDED AT
    AMBIENT TEMPERATURES.
Ventilation:LOCAL EXHAUST IS ADEQUATE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:SOLVENT-RESISTANT APRON OR OTHER IMPERVIOUS
    CLOTHING TO AVOID CONTAMINATING REGULAR CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXPOS:SAME NAPHTHA BOILING AS THIS PROD CAN PRDCE ADVERSE
    KIDNEY EFTS IN MALE RATS. EFTS WERE NOT OBSERVED IN SIMILAR STUDIES
    WITH FEMALE RATS. ING 2:THERE WAS NO CLINICAL EVIDENCE OF EFTS .
    HIGHLY UNLIKELY KIDNEY EFTS OBSERVED IN MALE RATS HAVE SIGNIFICANT
    IMPLICATIONS FOR HUMANS EXPOSED AT OR BELOW (ING 3)

==================  Physical/Chemical Properties  ==================

HCC:V4
Boiling Pt:B.P. Text:424F,218C
Vapor Pres:<2
Vapor Density:>5
Spec Gravity:0.8031 (H*20=1)
Evaporation Rate & Reference:<0.1 (BU AC = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:TRANSPARENT WATER-WHITE, CITRUS ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:FUMES SMOKE, CARBON MONOXIDE,
    ALDEHYDES AND OTHER DECOMPOSITION PRODUCTS, IN THE CASE OF
    INCOMPLETE COMBUSTION.

====================  Disposal Considerations  ====================

Waste Disposal Methods:ADVISE AUTHORITIES IF PROD HAS ENTERED/MAY ENTER
    SEWERS, WATERCOURSES/EXTENSIVE LAND AREAS. ASSURE CONFORMITY
    W/APPLIC GOVT REGS. CONTINUE TO OBSERVE PREC FOR VOLAT COMBUST VAPS
    FROM ABSORBED MATL. DI SPOSE OF ACCD TO LOCAL, STATE, (ING 7)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.