PPG INDUSTRIES -- ALKYD FLOOR/DECK EN WHITE/PASTEL, 3-110 -- 8010-00F004529
=====================  Product Identification  =====================

Product ID:ALKYD FLOOR/DECK EN WHITE/PASTEL, 3-110
MSDS Date:04/04/1991
FSC:8010
NIIN:00F004529
=== Responsible Party ===
Company Name:PPG INDUSTRIES
Address:ONE GATEWAY CENTER
City:PITTSBURGH
State:PA
ZIP:15222-1416
Country:US
Info Phone Num:412-492-5555
Emergency Phone Num:304-843-1300
CAGE:PPGIN
=== Contractor Identification ===
Company Name:PPG INDUSTRIES
Address:4325 ROSANNA DR
City:ALLISON PARK
State:PA
ZIP:15101-5000
Country:US
Phone:412-492-5555/304-843-1300
CAGE:PPGIN
Company Name:PPG INDUSTRIES INC CHEMICAL DIVISION
Address:ONE GATEWAY CENTER
City:PITTSBURGH
State:PA
ZIP:15222-1416
Country:US
Phone:304-843-1300
CAGE:93915

=============  Composition/Information on Ingredients  =============

Ingred Name:ALUMINUM SILICATE (AS NUISANCE DUST OR PARTICULATES NOT
    OTHERWISE REGULATED)
CAS:1302-76-7
RTECS #:BD1450000
Fraction by Wt: 5-10%
OSHA PEL:15 MG/M3 TOTAL DUST
ACGIH TLV:10 MG/M3 TDUST;8990

Ingred Name:TITANIUM DIOXIDE
CAS:13463-67-7
RTECS #:XR2275000
Fraction by Wt: 15-20%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293

Ingred Name:MEDIUM ALIPHATIC NAPHTHA (AROMATIC 100), PARAFFIN-NAPTHANES
    MINERAL SPIRITS  *93-4*
CAS:64742-88-7
Fraction by Wt: 20-25%
Other REC Limits:100 PPM
OSHA PEL:500 PPM
ACGIH TLV:100 PPM

Ingred Name:HYDROTREATED MIDDLE PETROLEUM DISTILLATE, PETROLEUM SOLVENT
CAS:64742-46-7
RTECS #:JN9379645
Fraction by Wt: 2-5%

Ingred Name:ISOPARAFFINIC HYDROCARBONS (NAPHTHA PETROLEUM),
    HYDROTREATED HEAVY, NON AROMATIC HEAVY NAPHTHA) ISOPAR G *93-4*
CAS:64742-48-9
Fraction by Wt: 10-15%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:INGESTION: HARMFUL/FATAL IF SWALLOWED.
    EYES: IRRITAION. SKIN: MODERATE IRRITATION. INHALATION: VAPOR &
    SPRAY MIST MAY BE HARMFUL IF INHALED. REPEATED EXPOSURE TO HIGH
    VAPOR CONCENTRATIONS MAY CAUSE IR RITATION OF THE RESPIRATORY
    SYSTEM & PERMANENT BRAIN & NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUE
    MAY BE HARMFUL/FATAL.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: WATERING, HEADACHES, NAUSEA, DIZZINESS, &
    LOSS OF COORDINATION, REDNESS, ITCHING, VISUAL DISTURBANCES. SKIN:
    DRYNESS, ITCHING, CRACKING, BURNING, REDNESS, SWELLING.

=======================  First Aid Measures  =======================

First Aid:INGESTION: IF SWALLOWED, DON'T INDUCE VOMITING. EYES: FLUSH
    IMMEDIATELY W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN: FLUSH
    IMMEDIATELY W/PLENTY OF WATER FOLLOWED BY WASHING W/SOAP & WATER.
    INHALATION : IF AFFECTED BY INHALATION OF VAPOR ORSPRAY MIST,
    REMOVE TO FRESH AIR. APPLY ARTIFICIAL RESPIRATION & OTHER
    SUPPORTIVE MEASURES AS REQUIRED. OBTAIN MEDICAL ATTENTION IN ALL
    CASES.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:104F
Lower Limits:0.9
Extinguishing Media:CLASS B EXTINGUISHERS/CO2/DRY CHEMICAL/UNIVERSAL
    AQUEOUS FILM FORMING FOAM TO EXTINGUISH NFPA CLASS II COMBUTIBLE
    LIQUID
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE. WATER SPRAY MAY BE
    USED TO COOL CLOSED CONTAINERS TO PREVENT PRESSURE
    BUILD-UP/POSSIBLE AUTO IGNITION/EXPLOSION WHEN EXPOSED TO HEAT.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
    FROM HEAT, ELECTRICAL EQUIPMENT, SPARKS, & OPEN FLAMES. CLOSED
    CONTAINERS MAY EXPLODE WHEN EXPOSE TO EXTREME HEAT.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PROVIDE MAXIMUM VENTILATION. ONLY PERSONNEL
    EQUIPPED W/PROPER RESP/SKIN/EYE PROTECTIVE SHOULD BE PERMITTED IN
    THE AREA. REMOVE ALL SOURCES OF IGNITION. TAKE UP SPILLED MATERIAL
    W/SANDDUST/VERMICULITE  OR PLACE INTO CONTAINERS FOR DISPOSAL.

======================	Handling and Storage  ======================

Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE
    QUANTITIES IN BLDGS DESIGNED/PROTECTED FOR STORAGE OF NFPA CLASII
    COMBUSTIBLE LIQUIDS.
Other Precautions:CONTAINERS SHOULD GROUNDED WHEN POURING. ALL CHEM.
    SUBSTANCES IN THIS PRODUCT COMPLY W/ALL APPLICABLE RULES/ORDERS
    UNDER THENVIRONMENTAL PROTECTION AGENCY'S TOXIC SUBSTANCE CONTROL
    ACT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NIOSH/MSHA-APPROVED (TC-23-C) SPRAY OR AIR
    SUPPLIED (TC-19C).
Ventilation:PROVIDE LOCAL EXHAUST VENTILATION TO KEEP AIR
Spec Gravity:1.11
Evaporation Rate & Reference:(BUOAC=100):10
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLVENT ODOR
Percent Volatiles by Volume:54.0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/STRONG ALKALIES/MINERAL ACIDS/OXIDIZING AGENTS.
Hazardous Decomposition Products:WELDING, BRAZING/FLAME-CUTTING ON
    SURFACES COATED W/THIS PRODUCT MAY PRODUCE FUMES INCLUDING: CO

====================  Disposal Considerations  ====================

Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
    WITH FEDERAL, STATE, AND LOCAL ENVIRONMENTAL CONTROL REGULATIONS.
    EMPTY CONTAINERS SHOULD BE RECYCLED OR DISPOSED OF THROUGH AN
    APPROVED WASTE MANAGEME NT FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.